Oficina principal
en el centro de Europa
Garantía
hasta 24 meses
hasta 24 meses
Mejores
precios
precios
Economía
del 15 al 55%
del 15 al 55%
Entrega
por todo el mundo
por todo el mundo
Todas las cargas
están aseguradas
están aseguradas
Entrega
gratis
gratis
En Famaga puede comprar Endress Hauser Vibronic Point level detection Nivotester FTL375P, al igual qu otras piezas
de la compañía Endress+Hauser con entrega por todo el mundo, incluso en su ciudad Dublin. Para solicitar precios, plazos de entrega
y otras características de producción de Endress+Hauser, por favor, rellene el formulario de retroalimentación o envíe la descripción de elementos necesarios
en el correo electrónico sales@famaga.us
Descripción
Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant The switching unit FTL375P is used for point level detection in liquid tanks and bulk material silos, also in hazardous explosion areas. Also suitable for liquid detection in pipes for dry running protection for pumps and overfill prevention for tanks with combustible or non-combustible liquids harmful to water. Up to 3 measuring devices for two-point control and point level detection. Functional safety up to SIL3 in accordance to IEC 61508 using Liquiphant with electronic insert FEL57.- Benefits
- Nivotester FTL375P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices)
- Intrinsically safe signal circuits Ex ia for use of measuring sensor in explosion hazardous areas
- Functional safety up to SIL2 through line monitoring....
- Nivotester FTL375P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices)
- Intrinsically safe signal circuits Ex ia for use of measuring sensor in explosion hazardous areas
- Functional safety up to SIL2 through line monitoring. Simplified proof testing to WHG/SIL by pressing push-button
- Racksyst plug-in card in Europa card format to DIN 41494, 4 HP wide, 3 HU high
- Inputs are galvanically isolated from each other, from the mains and from the outputs
- Field of application Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant.
- Ambient temperature: -20 to +70°C (-4 to +158°F)
- International explosion protection certificates, overfill prevention WHG, marine approvals
Completamos equipos
según su lista de compras
Este servicio brinda la máxima comodidad al cliente. Simplemente descargue la lista de equipos que necesita.
Enviamos...
Mensaje no ha sido enviado
Solicitud enviada
Наверх страницы
Fabricante
Endress+Hauser